Logo background Search

Copyright 2024 Electrical101.com All Rights Reserved.

Sitemap

Sitemap

Terms of Use

Privacy

About

Electrical 101

Bolt Bolt

How to Replace 4 Lamp Rapid Start Ballast with Instant Start

Question or Comment?

4 Lamp Rapid Start Ballast Diagram

Factory wiring

4 Lamp Rapid Start Ballast Replaced with Instant Start Diagram

After 4 Lamp Series Ballast is Replaced

4 lamp rapid start magnetic ballasts should be replaced with one 4 lamp instant start electronic ballast. Each lampholder has four separate connections.

1. Connect each of the individual blue wires from the instant start ballast to each pair of the lampholder individual wires (red and blue) of lamps 1 and 2.

2. Connect each of the individual red wires from the instant start ballast to each pair of the lampholder individual wires (red and blue) of lamps 3 and 4.

3. Connect one of the common yellow wires from the instant start ballast to the yellow pair of lampholder common wires of lamps 1 and 2. Connect the other common yellow wire from the instant start ballast to the yellow pair of lampholder common wires of lamps 3 and 4.

4 Lamp Series Ballast Wiring Diagram